Siemens SITOP
SITOP Add-on Modules
Request a quoteExpansion modules for increasing system availability up to total all-round protection
Siemens SITOP Add-on Modules is a series of Expansion modules for increasing system availability up to total all-round protection. SITOP offers you a unique range of perfectly integrable expansion modules for reliable protection against a wide variety of potential hazards on the primary and secondary side. The SITOP add-on modules allow the completely flexible expansion of SITOP power supply units and extension up to total, all-round protection.
FEATURES
SITOP redundancy module
- Highly secure DC supply thanks to a redundant design
- Reliable supply even when one power supply fails
- Compact redundancy modules for power supply units up to 48 V and 40 A
- 24-V/NEC Class 2 redundancy module limited to 100 VA
- Decoupling of parallel-connected power supply units to enhance performance or of series-connected power supply units to increase voltage
SITOP selectivity module
- Protection against overloads and short circuits in the 24-V circuit
- Reliable tripping, regardless of the line resistance
- SEL1200: switch-off characteristic for standard protection and high starting currents
- SEL1400/PSE200U: power limiting to meet high protection requirements by stabilizing the 24 V
- Sequential connection reduces total inrush current
- Common signaling contact or evaluation of individual channels
- SEL1200/1400: 8 outputs, each with diagnostics of voltage, current, set threshold, reason for disconnection (if applicable)
- PSE200U: 4 outputs with voltage measuring point for current (1 V ≙ 1 A)
SITOP buffer module
- Economical protection against power failure up to the seconds range
- Support for the power supply unit when the power demand temporarily increases
- High load current up to 40 A
- Only two lines connecting to the power supply unit
SITOP inrush current limiters
- Maximum service life of current-sensitive components like relays thanks to reduced current inrushes
- Space-saving, thanks to narrow width of only 18 mm
- Suitable for LOGO! modules and sub-distribution boards, thanks to its stepped profile
- Flexible installation on the DIN rail, on the wall or in various other locations
- Maximum plant configuration enabled
- Flexible application options at temperatures ranging from -40° Celsius to +70° Celsius
ORDERING INFORMATION
Redundancy Modules
| Part Number | Article Number | Description |
|---|---|---|
| PSU202U, 24 V/10 A | 6EP1964-2BA00 | SITOP PSE202U 10A Redundancy module Input/output: 24 V DC suitable for decoupling two SITOP power supplies with maximal per 5 A output current |
| PSE202U NEC Class 2, 24 V/100 W | 6EP1962-2BA00 | SITOP PSE202U NEC Class 2 Redundancy module Input/output: 24 V DC suitable for decoupling two SITOP power supplies Output power restricted to 100 VA |
| PSE202U, 24 V/40A | 6EP1961-3BA21 | SITOP PSE202U Redundancy module Input/output: 24 V DC/40 A suitable for decoupling two SITOP power supplies with maximal per 20 A output current |
| RED1200, 24/48 V/20 A | 6EP4346-7RB00-0AX0 | SITOP RED1200 redundancy module Input/output: 24/48 V DC/20 A Suitable for decoupling two SITOP power supplies with max. 10 A output current each |
| RED1200, 24/48 V/40 A | 6EP4347-7RB00-0AX0 | SITOP RED1200 redundancy module Input/output: 24/48 V DC/40 A Suitable for decoupling two SITOP power supplies with max. 20 A output current each |
Selectivity Modules
| Part Number | Article Number | Description |
|---|---|---|
| Diagnostic Module, 4x10 A | 6EP1961-2BA00 | SITOP select Diagnostics module 4-channel input: 24 V DC/40 A output: 24 V DC/4x 10 A Level adjustable 2-10 A |
| SEL1200 10 A 4x10 A | 6EP4437-7FB00-3CX0 | SITOP SEL1200 10 A Selectivity module 4-channel with switching characteristic Input: 24 V DC/40 A Output: 24 V DC/4x 10 A Threshold value adjustable 2-10 A With monitoring interface |
| SEL1200 5 A 8x5 A | 6EP4437-7FB00-3DX0 | SITOP SEL1200 5 A Selectivity module 8-channel with switching characteristic Input: 24 V DC/40 A Output: 24 V DC/8x 5 A Threshold adjustable 1-5 A With monitoring interface |
| SEL1200 10 A 8x10 A | 6EP4438-7FB00-3DX0 | SITOP SEL1200 Selectivity module 8-channel switching characteristic Input: 24 V DC/60 A output: 24 V DC/8 x 10 A Level adjustable 2-10 A with monitoring interface |
| SEL1400 10 A 4x10 A | 6EP4437-7EB00-3CX0 | SITOP SEL1400 10 A Selectivity module 4-channel with limiting characteristic Input: 24 V DC/40 A Output: 24 V DC/4x 10 A Threshold value adjustable 2-10 A With monitoring interface |
| SEL1400 5 A 8x5 A | 6EP4437-7EB00-3DX0 | SITOP SEL1400 5 A Selectivity module 8-channel with limiting characteristic Input: 24 V DC/40 A Output: 24 V DC/8x 5 A Threshold adjustable 1-5 A With monitoring interface |
| SEL1400 10 A 8x10 A | 6EP4438-7EB00-3DX0 | SITOP SEL1400 10 A Selectivity module 8-channel with limiting characteristic Input: 24 V DC/60 A output: 24 V DC/8x 10 A Threshold adjustable 2-10 A with monitoring interface |
Buffer Modules
| Part Number | Article Number | Description |
|---|---|---|
| PSE201U | 6EP1961-3BA01 | SITOP PSE201U buffer module Buffer time 100 ms to 10 s Depending on load current |
| BUF1200 | 6EP4231-7HB00-0AX0 | SITOP BUF1200 buffer module Buffer time 300 ms at 40 A Buffer t. depends on load current DC input 24 V |
Inrush Current Limiters
| Part Number | Article Number | Description |
|---|---|---|
| Inrush current limiter | 6EP1967-2AA00 | SITOP Switch on current limiter Ballast unit for SITOP Power supplies input: 100-480 V AC, 10 A max output: 100-480 V AC, 10 A max |
| Inrush current limiter LOGO! ICL230 | 6EP4683-6LB00-0AY0 | LOGO! ICL230 Inrush current limiter Input: 100-240 V AC Output: 100-240 V AC/5 A |
DOCUMENTS
Request a Quote or Speak to an Expert
Contact IndustrialComms for pricing, availability and expert guidance on the right product for your project.
Submit your details using our enquiry form and our team will respond promptly, or speak directly with our technical experts for immediate assistance.