RUGGEDCOM
RSG2200 Series
Request a quote
6GK6022 - 9-Port Managed Gigabit Ethernet Switch
The RuggedSwitch® RSG2200 is an industrially hardened, fully managed, modular Gigabit Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding utility substation and industrial environments.
The RSG2200’s superior ruggedized hardware design coupled with the embedded Rugged Operating System (ROS®), provides improved system reliability, and advanced cyber security and networking features making it ideal for creating mission critical, Gigabit networks or aggregating switches into a Gigabit backbone.
The RSG2200’s modular flexibility offers 1000BaseX fiber and 10/100/1000BaseTX copper port combinations. Support for front or rear mount connectors coupled with support for multiple fiber connector types (SFP,GBIC, LC, SC) without loss of port density makes the RSG2200 highly versatile and suitable for any application. The RSG2200 is packaged in a rugged galvanized steel enclosure with industrial grade DIN, panel, or 19” rackmount mounting options.
FEATURES
- up to 9-Gigabit Ethernet ports - copper and/or fiber
- up to 9 100FX Fiber Fast Ethernet ports
- 2 port modules for tremendous flexibility
- Supports many types of fiber (Multimode, singlemode, directional single strand)
- Non-blocking, store and forward switching
- Long haul optics allow Gigabit distances up to 70km
- Multiple connector types (LC, SC, SFP, GBIC)
CONFIGURATOR
| Model | |
|---|---|
| 6GK6022-0AS2 - Main - Mount - PS1 - PS2 - S1 - S2 - S3 - S4 - S5 - MOD | Industrially hardened, fully managed modular Gigabit Ethernet switch, up to 9-Gigabit Ethernet ports copper and/or fiber; up to 9 100FX Fiber Fast Ethernet ports; 2 port modules |
| Main: Ethernet and Power Connectors | |
|---|---|
| B | Ethernet on rear; LED panel on front; power connector on rear |
| C |
Ethernet on front; LED panel on front; power connector on rear |
| D |
Ethernet on rear; LED panel on top; power connector on rear |
| E |
Ethernet on front; LED panel on top; power connector on rear |
| Mount: Mounting Options | |
|---|---|
| A |
No mounting option |
| D |
19” rack mounting kit |
| E |
DIN/rail and panel mounting kit |
| F |
19” rack, DIN/rail and panel mounting kit |
| PS1: Power Supply 1 | |
|---|---|
| 1 | 24 VDC (10 – 36 VDC) with screw terminal block |
| 2 |
48 VDC (36 – 72 VDC) with screw terminal block |
| 3 |
88 – 300 VDC / 85 – 264 VAC with screw terminal block |
| 4 |
24 VDC (10 – 36 VDC) with pluggable terminal block |
| 5 |
48 VDC (36 – 72 VDC) with pluggable terminal block |
| 6 |
88 – 300 VDC / 85 – 264 VAC with pluggable terminal block |
| PS2: Power Supply 2 (terminal block must be equal to power supply 1) | |
|---|---|
| 0 | No power supply 2 |
| 1 | 24 VDC (10 – 36 VDC) with screw terminal block |
| 2 | 48 VDC (36 – 72 VDC) with screw terminal block |
| 3 | 88 – 300 VDC / 85 – 264 VAC with screw terminal block |
| 4 | 24 VDC (10 – 36 VDC) with pluggable terminal block |
| 5 | 48 VDC (36 – 72 VDC) with pluggable terminal block |
| 6 | 88 – 300 VDC / 85 – 264 VAC with pluggable terminal block |
| Z Options | S1 | S2 | S3 | S4 |
|---|---|---|---|---|
| No module | A00 | B00 | C00 | D00 |
| 2 x 10/100/1000BASE-TX RJ45 | A01 | B01 | C01 | D01 |
| 2 x 1000BASE-SX, multi-mode, 850 nm, LC, 500 m | A02 | B02 | C02 | D02 |
| 2 x 1000BASE-LX, single-mode, 1310 nm, SC, 10 km | A03 | B03 | C03 | D03 |
| 2 x 1000BASE-LX, single-mode, 1310 nm, LC, 10 km | A04 | B04 | C04 | D04 |
| 2 x 1000BASE-LX, single-mode, 1310 nm, SC, 25 km | A05 | B05 | C05 | D05 |
| 2 x 1000BASE-LX, single-mode, 1310 nm, LC, 25 km | A06 | B06 | C06 | D06 |
| 2 x 1000BASE-LX SFP, blank (no optical transceiver) | A07 | B07 | C07 | D07 |
| 2 x 1000BASE-SX SFP, multi-mode, 850 nm, LC, 500 m (Incl. 2 x SFP1122-1SX) | A08 | B08 | C08 | D08 |
| 2 x 1000BASE-LX SFP, single-mode, 1310 nm, LC, 10 km (Incl. 2 x SFP1132-1LX10) | A09 | B09 | C09 | D09 |
| 2 x 1000BASE-LX SFP, single-mode, 1310 nm, LC, 25 km (Incl. 2 x SFP1132-1LX25) | A10 | B10 | C10 | D10 |
| 2 x 1000BASE-LX SFP, single-mode, 1550 nm, LC, 70 km (Incl. 2 x SFP1132-1LX70) | A11 | B11 | C11 | D11 |
| 2 x 1000BASE-LX GBIC, blank (no optical transceiver) | A12 | B12 | C12 | D12 |
| 2 x 1000BASE-LX GBIC, single-mode, 1310 nm, SC, 10 km | A13 | B13 | C13 | D13 |
| 2 x 1000BASE-LX GBIC, single-mode, 1310 nm, SC, 25 km | A14 | B14 | C14 | D14 |
| 2 x 1000BASE-LX GBIC, single-mode, 1550 nm, SC, 70 km | A15 | B15 | C15 | D15 |
| 2 x 100BASE-FX, multi-mode, 1300 nm, ST | A16 | B16 | C16 | D16 |
| 2 x 100BASE-FX, multi-mode, 1300 nm, SC | A17 | B17 | C17 | D17 |
| 2 x 100BASE-FX, multi-mode 1300 nm, LC | A18 | B18 | C18 | D18 |
| 2 x 100BASE-FX, multi-mode 1300 nm, MTRJ | A19 | B19 | C19 | D19 |
| 2 x 100BASE-FX, single-mode 1310 nm, ST, 20 km | A20 | B20 | C20 | D20 |
| 2 x 100BASE-FX, single-mode 1310 nm, SC, 20 km | A21 | B21 | C21 | D21 |
| 2 x 100BASE-FX, single-mode 1310 nm, LC, 20 km | A22 | B22 | C22 | D22 |
| 2 x 100BASE-FX, single-mode 1310 nm, SC, 50 km | A23 | B23 | C23 | D23 |
| 2 x 100BASE-FX, single-mode 1310 nm, LC, 50 km | A24 | B24 | C24 | D24 |
| 2 x 100BASE-FX, single-mode, 1310 nm, SC, 90 km | A25 | B25 | C25 | D25 |
| 2 x 100BASE-FX, single-mode 1310 nm, LC, 90 km | A26 | B26 | C26 | D26 |
| 2 x 1000BASE-TX, SFP, RJ45 (Incl. 2 x SFP1112-1) | A27 | B27 | C27 | D27 |
| Z options | S5: Slot 5 |
|---|---|
| No module | E00 |
| 1 x 10/100/1000BASE-TX RJ45 | E01 |
| 1 x 1000BASE-SX, multi-mode, 850 nm, LC, 500 m | E02 |
| 1 x 1000BASE-LX, single-mode, 1310 nm, SC, 10 km | E03 |
| 1 x 1000BASE-LX, single-mode, 1310 nm, LC, 10 km | E04 |
| 1 x 1000BASE-LX, single-mode, 1310 nm, SC, 25 km | E05 |
| 1 x 1000BASE-LX, single-mode, 1310 nm, LC, 25 km | E06 |
| 1 x 1000BASE-LX SFP, blank (no optical transceiver) | E07 |
| 1 x 1000BASE-SX SFP, multi-mode, 850 nm, LC, 500 m (Incl. 1 x SFP1122-1SX) | E08 |
| 1 x 1000BASE-LX SFP, single-mode, 1310 nm, LC, 10 km (Incl. 1 x SFP1132-1LX10) | E09 |
| 1 x 1000BASE-LX SFP, single-mode, 1310 nm, LC, 25 km (Incl. 1 x SFP1132-1LX25) | E10 |
| 1 x 1000BASE-LX SFP, single-mode, 1550 nm, LC, 70 km (Incl. 1 x SFP1132-1LX70) | E11 |
| 1 x 1000BASE-LX GBIC, blank (no optical transceiver) | E13 |
| 1 x 1000BASE-LX GBIC, single-mode, 1310 nm, SC, 10 km | E14 |
| 1 x 1000BASE-LX GBIC, single-mode, 1310 nm, SC, 25 km | E15 |
| 1 x 1000BASE-LX GBIC, single-mode, 1550 nm, SC, 70 km | E16 |
| 1 x 100BASE-FX - multi-mode, 1300 nm, ST | E17 |
| 1 x 100BASE-FX - multi-mode, 1300 nm, SC | E18 |
| 1 x 100BASE-FX - multi-mode 1300 nm, LC | E19 |
| 1 x 100BASE-FX - multi-mode 1300 nm, MTRJ | E20 |
| 1 x 100BASE-FX - single-mode 1310 nm, ST, 20 km | E21 |
| 1 x 100BASE-FX - single-mode 1310 nm, SC, 20 km | E22 |
| 1 x 100BASE-FX - single-mode 1310 nm, LC, 20 km | E23 |
| 1 x 100BASE-FX - single-mode 1310 nm, SC, 50 km | E24 |
| 1 x 100BASE-FX - single-mode 1310 nm, LC, 50 km | E25 |
| 1 x 100BASE-FX - single-mode, 1310 nm, SC, 90 km | E26 |
| 1 x 100BASE-FX - single-mode 1310 nm, LC, 90 km | E27 |
| MOD: Manufacturing Modifications | |
|---|---|
| 0 |
Standard |
| 1 |
Conformal Coating |
Notes:
1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices.
2 These transceivers have an operating temperature range of -20 °C to +85°C.
All other transceivers have an operating temperature range of -40°C to +85°C
3 SFP plugable optics that consist of a blank cage (FG50 for dual, 1FG50 for single)
plus specified fiber optic interface(s) installed
4 GBIC plugable optics that consist of a blank cage (FG70 for dual, 1FG70 for single)
plus specified fiber optic interface(s) installed
5 Power Supply 1 and 2 must be either both screw terminal block or both pluggable terminal block
6 Switch must be ordered with at least one module installed
DOCUMENTS
Request a Quote or Speak to an Expert
Contact IndustrialComms for pricing, availability and expert guidance on the right product for your project.
Submit your details using our enquiry form and our team will respond promptly, or speak directly with our technical experts for immediate assistance.